TOP GUIDELINES OF DP50RB

Top Guidelines Of Dp50rb

Top Guidelines Of Dp50rb

Blog Article

Guidance 4D probe; understand the probe by means of the ID code; swap the 4D generate signal through the  electrical relay to produce the 4D probe work Ordinarily. 4.two.2 Major board The key board may very well be divided into two elements: front-conclude of the most crucial board and back-finish of the key board.

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

Analyzing individuals in today’s demanding surroundings necessitates innovative know-how that enables clinicians to generate rapid and assured diagnoses. The flexibility of your DP-50 expands your clinical utility though helping to make improvements to affected individual treatment.

Once you stop the scanning and also the impression seize, it is best to energy from the program and disconnect the system in the AC electricity provide, then pull out AC electricity cables. Site 109: Battery Connecting Board

Learn better diagnostic facts by extended check out of the anatomical composition on all convex probes.

Website page a hundred forty five Cleanse control panel Resources: dry comfortable cloth, delicate soapy h2o  Strategy:  Use dry comfortable fabric to scrub the area of your procedure. When the method is dirty, moisten the soft fabric with gentle soapy water and wipe off any stains. Use dry soft fabric to remove any humidity and allow all hard surfaces to completely air-dry. Page 146: Clean up The Peripherals

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Mindray’s new era of black & white ultrasound method, DP-fifty Professional, is provided with State-of-the-art imaging systems making it possible for further penetration and quicker impression acquisition with bigger resolution.

This manual may perhaps referring to information and facts shielded by copyright or patents and would not Express any license under the patent legal rights or copyright of Mindray, or of Many others. Web site 9: Statement

iZoom™ allows accurate viewing of impression from length iWorks™ Protocol will help standardize workflow and decrease Examination times

Cookies are essential to the proper operating of a internet site. To boost your practical experience, we use cookies to remember log-in particulars and provide protected log-in, acquire studies to optimize internet site operation, and produce articles customized on your pursuits.

Take note: Just before inserting the connector in the probe port, inspect the connector pin. Should the pin is bent, never make use of the probe until finally it's been inspected / repaired / changed. Installing Peripherals For that products from the supported peripherals, remember to consult with “two.

Just after replacing the CPU module, essential file must be generated Again according to the new MAC tackle and composed into HDD on the equipment. Or else, the configuration function in the products will likely be lost. Immediately after getting rid of the CPU module, Remove panhead screws with washers (12 M3X6) preset on the principle device box, you normally takes off the board. Web site 118 Determine 8-29 Disassemble the User interface Assembly (1) Maintain the upper edge of control panel assembly, and open up the control panel. Determine eight-30 Disassemble the User interface Assembly (2) Following getting rid of one countersunk head self-tapping screw PT3X10 mounted about the control panel and choose out the plug on the keyboard and the principle device connecting cables, you could possibly eliminate the user interface assembly.

Efficiency Test 5.5.1 Check Method Resolution Dp50rb Detection depth Geometric Position Precision Blackout spot take a look at Document the exam photographs 5.five.2 Examination Written content The picture used here is just for reference, stay with the picture impact in the actual Notice: problem. Specifications: Screen: set the contrast and brightness in the clinical software price (or perhaps the default standing) Operation atmosphere: dark room, simulating the scientific application setting. Website page 76 In situation that the transverse resolution tests targets are horizontally shown, document the minimum length of two targets that could be Obviously recognized. Repeat the Procedure over for the transverse resolution screening targets at other depths. As shown in determine beneath. Axial resolution ... Page 77 When utilizing the convex probe, hold the transverse resolution tests targets to NOTE: be shown close to the midline. When using a linear probe with steer functionality, usually do not activate the steer function when execute the transverse resolution exam. Zoom while in the location in which the targets Found if essential. The diameter with the target level at a particular depth is equivalent into the transverse resolution on the depth. Site seventy eight five.

A sensible new shape, Increased mobility and practical operation make DP-fifty well matched for all medical options.

five.two.three Geometric positioning precision Longitudinal geometric positioning accuracy  Exam Phase: Do changes as the best way in screening the utmost depth. Report the gap by 20mm Each individual section around the longitudinal targets line utilizing the measurement caliper; Find the worth with the best error (to 20mm), determine the accuracy using the method underneath The measurement caliper really should be positioned within the higher edge of the target, NOTE:... Website page 79 Transverse geometric positioning precision  Exam Action: Protect the scan surface area with the phantom with drinking water or few gel, gently contact the probe Using the scan area Change the depth, earning the transverse targets for being shown while in the image. Adjust the focus stage to generally be posited beside the transverse targets (the typical just isn't clear) Change parameters like acquire, TGC, earning Each and every transverse targets to become Evidently displayed. Site eighty five.5.two.four Blackout Spot Test Phase: Address the scan area of the phantom with water or pair gel, Carefully Get in touch with the probe Along with the scan area Alter the depth at a lower worth, and set the main focus at the closest place to the scan surface. Reduce the worth of parameters like AP, Achieve until the background noise just may be noticed. Page eighty one: Computer software Enhance And Maintenance